Bolt connection terminal block - OTTA 6 - 0790433
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bolt connection terminal block, Connection method: Bolt connection, Cross section: 0.1 mm² - 6 mm²,
AWG: 26 - 10, Width: 11 mm, Color: gray, Mounting type: NS 35/7,5, NS 35/15, NS 32
Key Commercial Data
Packing unit
1 pc
GTIN
Weight per Piece (excluding packing)
23.188 g
Custom tariff number
85369010
Country of origin
India
Technical data
General
Number of levels
1
Number of connections
2
Nominal cross section
6 mm²
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8 kV
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Connection in acc. with standard
IEC 60947-7-1
Nominal current IN
41 A
Maximum load current
41 A (with 6 mm² conductor cross section)
03/29/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/0790433
Bolt connection terminal block - OTTA 6 - 0790433
Technical data
General
Nominal voltage UN
800 V (the nominal voltage applies to insulated cable lugs)
Open side panel
Yes
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Finger protection
guaranteed
Result of surge voltage test
Test passed
Surge voltage test setpoint
9.8 kV
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
2 kV
Result of the test for mechanical stability of terminal points (5 x conductor
connection)
Test passed
Result of bending test
Test is not applicable
Tensile test result
Test is not applicable
Result of tight fit on support
Test passed
Tight fit on carrier
NS 32/NS 35
Setpoint
5N
Result of voltage-drop test
Test passed
Requirements, voltage drop
≤ 3.2 mV
Result of temperature-rise test
Test passed
Short circuit stability result
Test passed
Conductor cross section short circuit testing
6 mm²
Short-time current
0.72 kA
Result of aging test
Test is not applicable
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
30 s
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Static insulating material application in cold
-60 °C
Dimensions
Length
43.5 mm
Width
11 mm
Height NS 35/7,5
52 mm
Height NS 35/15
59.5 mm
Height NS 32
57 mm
Connection data
Conductor cross section solid min.
0.1 mm²
Conductor cross section solid max.
6 mm²
03/29/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/0790433
Bolt connection terminal block - OTTA 6 - 0790433
Technical data
Connection data
Conductor cross section flexible min.
0.1 mm²
Conductor cross section flexible max.
6 mm²
Conductor cross section AWG min.
26
Conductor cross section AWG max.
10
Screw thread
M4
Tightening torque, min
1.5 Nm
Tightening torque max
1.8 Nm
Connection method
Bolt connection
Connection in acc. with standard
DIN 46 234
Min. cross section
0.1 mm²
Max. cross section
6 mm²
Hole diameter
4.3 mm
Bolt diameter
4 mm
Connection in acc. with standard
DIN 46237
Min. cross section
0.5 mm²
Max. cross section
2.5 mm²
Hole diameter
4.3 mm
Bolt diameter
4 mm
Standards and Regulations
Connection in acc. with standard
CSA
IEC 60947-7-1
DIN 46 234
DIN 46237
Flammability rating according to UL 94
V0
Classifications
eCl@ss
eCl@ss 4.0
27141120
eCl@ss 4.1
27141120
eCl@ss 5.0
27141120
eCl@ss 5.1
27141120
eCl@ss 6.0
27141120
eCl@ss 7.0
27141120
eCl@ss 8.0
27141120
eCl@ss 9.0
27141120
03/29/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/0790433
Bolt connection terminal block - OTTA 6 - 0790433
Classifications
ETIM
ETIM 2.0
EC000897
ETIM 3.0
EC000897
ETIM 4.0
EC000897
ETIM 5.0
EC000897
UNSPSC
UNSPSC 6.01
30211811
UNSPSC 7.0901
39121410
UNSPSC 11
39121410
UNSPSC 12.01
39121410
UNSPSC 13.2
39121410
Approvals
Approvals
Approvals
CSA / UL Recognized / VDE Zeichengenehmigung / GL / PRS / IECEE CB Scheme / EAC / EAC
Ex Approvals
Approvals submitted
Approval details
CSA
mm²/AWG/kcmil
22-10
Nominal current IN
30 A
Nominal voltage UN
600 V
03/29/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/0790433
Bolt connection terminal block - OTTA 6 - 0790433
Approvals
UL Recognized
Nominal current IN
30 A
Nominal voltage UN
600 V
VDE Zeichengenehmigung
mm²/AWG/kcmil
6
Nominal current IN
41 A
Nominal voltage UN
800 V
GL
PRS
IECEE CB Scheme
mm²/AWG/kcmil
6
Nominal current IN
41 A
Nominal voltage UN
800 V
EAC
EAC
Drawings
03/29/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/0790433
Bolt connection terminal block - OTTA 6 - 0790433
Circuit
diagram
Circuit diagram
1 = cover
2 = insertion bridge
3 = partition plate
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/29/2016 Page 6 / 6